vertical cyclone separator removal mechanism uses electric motor to drive the bias wheel. The connecting rod makes the bag vibrate and removes the dust on the surface of the bag. Its control installation is divided into two kinds: automatic control and manual control. Automatic control means that when the fan continues the task, the single-machine bag dust collector flying mechanism actively vibrates dust on time, the manual fan dust collector stops the active task of the flying mechanism, the active stop after tens of seconds, can also start the dust cleaning motor at any time according to the demand, the cleaning time is adjusted by the user time relay. vertical cyclone separator, dust catcher is a small volume, dust removal air purification equipment. Suitable for all kinds of vertical dust production points, flexible and convenient, local dust collection, local treatment, can be clean air. The basic structure is composed of dust removal box, centrifugal fan, filter bag (filter cylinder), dust collector and microcomputer controller, etc. The dust is sucked into the dust collector box by the negative pressure of the fan through the suction pipe, and the coarse dust is initially filtered by the filter and directly drops to the dust collector by gravity. The fine dust is captured by the filter on the outer surface. The clean gas flows into the clean room after filtration, decomposition and purification through the filter element, and is discharged from the outlet by the fan.

The parts to be checked when using vertical cyclone separator for the first time are as follows:

I. Fan rotation direction, speed, bearing vibration and temperature.

2. Whether the treated air volume and the pressure and temperature of each test point are consistent with the design.

Three, the installation of the filter bag, after the use of whether there is bag drop, loose mouth, wear and other conditions, after the operation can be judged by the discharge of the chimney.

Four, we should pay attention to whether there is condensation in the bag room and whether the ash discharge system is smooth. Prevent plugging and corrosion, serious ash accumulation will affect the production of the main engine.

Five, cleaning cycle and cleaning time adjustment, this work is an important factor about the dust collection performance and operation status. If the cleaning time is too long, the attached dust layer will be removed and become the cause of filter bag leakage and damage. If the cleaning time is too short, the dust on the filter bag has not been cleared off, and the filtration operation is resumed, the resistance will be recovered quickly and gradually the clinical effect will be the main effect, affecting its use effect.

The installation of vertical cyclone separator should be completed after all the installation work including stable thermal insulation performance, and the spray pipe should be removed before the bag filter is installed. When handling and storing vertical cyclone separator, attention should be paid to prevent the bag dust collector from contacting and colliding with the surrounding hard objects and sharp corner objects. It is forbidden to step on the bag and put heavy pressure on it to avoid damage. Installation environment requirements: The installation site should be adequately lit, and no devices or sundry materials unrelated to installation are allowed. During the process, smoking is prohibited, welding and cutting in any form or any part is prohibited, lighting lighting with lighters and matches is prohibited in the case of power failure. After the installation, the installation tools should be counted to avoid missing into the bag dust collector and damaging the bag dust collector. It is recommended to install by two people, one person to fold the bag lengthwise into the flower plate hole, the other person to grab and open the bag dust collector in rolls. The cage frame should be centered and placed gently to protect the vertical during installation. After installing a cloth bag dust collector, check whether the joint joint is sealed and whether the sealing position is correct. Check whether it is vertical from the ash hopper. If it is found that the bottom of the bag dust collector meets or is incorrect, it is necessary to make a record and adjust it in time under the guidance of technical personnel.